The GX-2012 is a portable multi-gas detector that delivers accurate readings. It has 3 operating modes: normal, leak check, and bar hole, with adjustable display ranges. The model has an auto-ranging display of % LEL and % volume, and is configured to detect combustibles in the air such as ppm LEL, % volume methane, O2, CO and H2S.
Equipped with vibration, visual, and audible alarms, the GX-2012 is able to inform the user of any gas detection efficiently. It also has an automatic backlight during alarms.
Additional features of the GX-2012 includes visual and audible pulses change with gas concentration, barhole test mode for underground leak checks, 0 to 100% volume methane option, and interchangeable lithium ion or alkaline battery packs.
Personal Four Gas Monitor GX-2012 MED
Features
- Monitors ppm LEL, % volume methane, O2, CO and H2S
- 0 to 100% volume methane option
- Auto-ranging display of % LEL and % volume
- 3 Operating modes: Normal, leak check, & bar hole
- PPM leak detector
- Adjustable display ranges
- Visual / audible pulses change with gas concentration
- CO display in leak check mode
- Bar hole test mode for underground leak checks
- Internal sample drawing pump with up to 100 feet range
- Vibration, visual, and audible alarms
- Automatic backlight during alarms
- Lithium ion or alkaline battery packs (interchangeable)
- Intrinsically safe, ATEX/IECEx/CE or CSA/CE (Optional)
Overview
With the GX-2012, you have multiple tools in one instrument. Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in it’s Normal Operating mode; for leak investigation in Leak Check mode; and for underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto range from % LEL to % volume. This is ideal for line purge testing.
Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide).
The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.
Application
- Personal monitoring
- Confined space entry
- Refineries / petrochemical
- Chemical plants
- Hazardous material
- Water / wastewater treatment
- Fire services
- Mining
Specifications
| Gas Detected | Combustible Gases (Methane as standard) |
% Volume Methane |
Oxygen (O2) | Hydrogen Sulfide (H2S) | Carbon Monoxide (CO) |
| Detection Principle | Catalytic combustion | Thermal conductivity | Galvanic cell | Electrochemical cell | |
| Detection Range | 0 ~ 100% LEL 0 ~ 500 / 1,000 / 2,000 / 5,000 ppm |
0 ~ 100% Vol. | 0 ~ 40% Vol. | 0 ~ 100 ppm (optional 0-500 ppm) |
0 ~ 500 ppm |
| Accuracy Statement (whichever is greater) |
± 5% of reading or ± 2% LEL(LEL mode only) |
± 5% of reading or ± 2% of full scale | ± 0.5% O2 | ± 5% of reading or ± 2 ppm H2S | ± 5% of reading or ± 5 ppm CO |
| Sampling Method | Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter | ||||
| Display | Digital LCD with 7 segments, auto backlight during alarm | ||||
| Preset Alarms (User Adjustable) |
1st alarm 10% LEL 2nd alarm 50% LEL Over alarm 100% LEL |
No alarms for % Vol. CH4 |
Low alarm 19.5% High alarm 23.5% Over alarm 40.0% | 1st 5 ppm 2nd 30 ppm TWA 10 ppm STEL 15 ppm Over 100 ppm |
1st 25 ppm 2nd 50 ppm TWA 25 ppm STEL 200 ppm Over 500 ppm |
| Alarms Types | Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error |
||||
| Alarm Methods | Gas alarms: Flashing lights, two tone buzzer, and vibration Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration |
||||
| Operating Temp. & Humidity | -20°C to +50°C (-4°F to 122°F) 0 to 95% RH, non-condensing |
||||
| Response Time | Within 30 seconds (T90) | ||||
| Continuous Operation | Alkaline battery: 15 hours Li-Ion battery: 10 hours 70°F (21°C) |
||||
| Power Source | Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable | ||||
| Safety Rating | ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available) | ||||
| Dimension & Weight | Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces) | ||||
| Case Material | High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding | ||||
| Controls | Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT | ||||
| Standard Accessories |
|
||||
| Optional Accessories |
|
||||
| Configurations | 1, 2, 3, 4, or 5 sensor units Li-Ion or alkaline battery pack options |
||||
| Warranty | Two years material and workmanship | ||||
Parts

| Part # | Description | |
| 1. | 17-1001RK | Tapered rubber inlet nozzle, 4”, RP-6 / GX-2003 / GX-2012 / Gas Tracer |
| 2. | 21-1833RK | Filter holder, clear plastic, GX-2003 |
| 3. | 33-1031RK | Cotton balls, filters for probe, bag of 25 |
| 4. | 33-0159RK | Teflon filter disc, 10 pieces, RP-6 / GX-2003 |
| 5. | 33-1112RK | Wire mesh disk filter, RP-6 / GX-2003 / GX-2012, 10 pack |
| 6. | 21-1890RK | Top cover assembly, GX-2012 / Gas Tracer |
| 7. | 30-0022RK | Pump replacement for GX-2012 and RP-2009, with cable and connector |
| 8. | 21-1889RK | Main case assembly, GX-2012 |
| 9. | 07-6024RK | Battery pack gasket, GX-2012 / Gas Tracer |
| 10. | 07-6025RK | Main case gasket, GX-2012 / Gas Tracer |
| 11. | 51-1125RK | LCD display, GX-2012 / Gas Tracer |
| 12. | 57-2043RK | CPU PC board assembly, GX-2012 |
| 13. | 49-1406RK | Battery, lithium, CR 1220, for main PCB, GX-2012 / Gas Tracer |
| 14. | 30-1053RK | Vibration motor, GX-2003 / GX-2012 / Gas Tracer |
| 15. | 10-1090RK | Tap tight screw M2x4.5 mm, phillips self-tapping |
| 16. | 57-2041RK | Sensor PC board assembly, GX-2012 |
| 17. | 07-6026RK | Sensor gasket, GX-2012 / Gas Tracer |
| 18. | 33-7114RK | Filter disk, H2S scrubber, 5 pack, for combustible diffusion port |
| 19. | 33-7102RK | Filter, charcoal, for CO sensor, pack of 5 GX-2009 / GX-2012 / Gas Tracer / GX-2001 |
| 20. | 21-1892RK | Sensor cap assembly, GX-2012 |
| 21. | 13-0118RK | Belt clip, GX-2012 / Gas Tracer |
| 22. | 49-1615RK | Batter pack, lithium ion, GX-2012 / Gas Tracer |
| 23. | 49-1616RK-01 | Alkaline Battery pack cover with gasket, GX-2012 / Gas Tracer |
| 24. | 49-1616RK-02 | Alkaline Battery pack without cover with gasket, GX-2012 / Gas Tracer |
| 25. | 13-0112RK | Wrist strap |
| 26. | 10-1108RK | Screw M2 x 16 |
| 27. | 10-1093RK | Screw M2 x 6 SUS304 |
| 28. | 10-1091RK | Screw M2 x 5 SUS |
| 29. | 10-1092RK | Truss screw M2 x 5 |
| 30. | OS-BM2 | O2 sensor OS-BM2 |
| 31. | NC-6264A NC-6264B (CSA version) |
LEL sensor (non CSA) LEL sensor for GX-2012 CSA |
| 32. | ES-1821 | CO sensor ES-1821 |
| 33. | ES-1827I | H2S sensor ES-1827I |
| 34. | TE-7561 | VOL sensor TE-7561 |
| 35. | SH-8641 | PPM sensor SH-8641, Gas Tracer |
| 36. | 49-1616RK | Alkaline Battery pack without batteries with gasket, GX-2012 / Gas Tracer |
Video
Downloads
|
GX-2012 Software |
||
|
GX-2012 Data Logger Management Program Operator’s Manual 3MB |
GX-2012 Data Logger Program 31MB version 05656 |
|
|
GX-2012 Literature |
||
|
GX-2012 Manuals |
||